E-mail: newsales12@vip.163.com
Tel: +86-15829050512
Contact Us

Address: Unit3.Building1, No.3 Courtyard, Pailou Alley Dongguan South Street, Beilin Distrct, Xi'an, Shaanxi, China

Tel: +86-15829050512

Fax: +86-029-82490435

E-mail:newsales12@vip.163.com

Home > News > Content

News

Electromagnetic Flowmeter Rosemount

May 24, 2016

Rosemount Magnetic  ;Flowmeter Supplier ;


Basic Info.

Model NO.:8700

Accuracy:0.5%

Main Application:Water, Wastewater, Corrosive Liquid/Gas

Size:Dn15-2000

Sensor:Tube/Flange

Application:Industrial Production

Type:Electromagnetic Flow Meter

Measuring Media:Liquid

Measuring Principle:Electrical Principles

Certification:GB, CE, SGS, ISO

Package:Carton

Trademark:GN

Origin:China

Medium:10-1000

Flow Range:0.16-25000 M³/H

Connection:Flange

Output:Pulse/4-20mA

Lining Material:PTFE/Rubber

Electrode Material:Ss316

Body Material:Carbon Steel/Ss304

Power Supply:220V/24V/Lithium Battery

Pressure:10bar

Type and IP Code:Integrated Type IP65, Remote Type IP68

HS Code:9026100000

Production Capacity:5000PCS/Month


Product Description

; ;Electromagnetic FlowmeterWorking principleIts measuring principle bases on Faraday electromagnetic induction law:When the liquid flow through the measuring pipe which all around magnetic field, the two vertical direction will have the induced electromotive force which is proportional with the mean velocity of stream.Flowmeter consists of sensor and converter. Converter transfer field current to inner loop of the sensor to engender magnetic field. Conductivity liquid flow through the measuring pipe and get induced force because of cutting magnetic line. By then the electrode around the pipe wall incept induced force and transfer them to converter through signal wire. Converter filer induced force, spread, calculate and exchange them into proportional standard current signal and frequency signal. ;Brief ; ;introduction1.it ;can ;measure ;all ;kinds ;of ; ;electronic ;conductivity ;liquid, ;such ;as ;corrosive ;liquid ;, ;mud ;and ;slurry ;,water ;etc. ;2.The ;result ;cannot ;be ;affected ;by ;temperature, ;pressure, ;viscosity ;and ;dens ity.3.Flow ;sensor ;and ;intelligent ;converter ;compact ;or ;separately ;composes ;a ;com plete ;flowmeter. ;
;Main ;features1.No ;move ;assembly, ;no ;abrasion ;2.Measuring ;range ;rate: ;1:1003.No ;flow ;enhance ;equipment4.Suits ;for ;various ;of ;electronic ;conductivity ;liquid5.No ;affect ;from ;temperature, ;viscosity, ;pressure ;and ;density6.Anti- corrosion7.Measure ;both ;to ;and ;reverse ;flow8.Huge ;display, ;easy ;operate9.Long- term ;EEPROM ;to ;save ;data ;when ;lose ;power10.Support ;MODBUS/HART ;communication ;protocol11.Wide ;working ;volts ;range12.Self ;diagnose ;Series of products


Production line

Installation

Payment Terms ; ;1.Loading Port: Shanghai China2. ;Samples Leading Time: 3-7 working ;days3. ;Delivery Time: Within 7-15 days after payment4.Payment: ; T/T, Western Union, Paypal ; ;After-sales serviceWe promise to deliver the following after-sales service:1. Warranty: The warranty period is 12 months starting from the shipping date;2. Customers will enjoy free repair services for failures found within the warranty due to manufacturing quality;3. For on-site services not arising from manufacturing quality, we shall charge a certain service fee at our discretion based on actual charges incurred such as travel expense; ;4. We provide paid repair services for meter damages not arising from manufacturing quality issues or meter damages not within the scope of warranty. ; ;Parameters: ;

DN

6mm~~2000mm

PN

PN6 , PN10 , PN16 , PN25 , PN40 , PN63 , PN100 , PN160 , PN250 , PN420

Electrode ;material

316L

Lining ;material

PTFE ;or ;customize

Medium ;tem

0~70°C , max ;is ; ;180°C

Shell ;material

carbon ;steel

Protection ;grade

IP65 , IP67 ; ; ;and ;IP6

Connection

all ;applys( eg : BS ;EN1092-1 )

;
Converter ;technical ;data
;

Current ;output

4~20Ma

Frequency ;output

No ;resource ;pulse :
High ;level=external ;power ;supply-1V
External ;volts≤30 ;V
Low ;level ≤ 0.5V
Load ;current ≤ 50 ;mA
Max.frequency ;output ;:5KHz .
Frequency ;of ;pulse ;output: ; 0~5Hz .

Display

With ;8digit ;LCD ;display

Display ;unit

Instantaneous ;flow ;units ; : m 3  ;/h , ; m 3  ;/m , m 3  ;/s , L/h , L/m , ; L/s , G/h , G/m , G/s . ; Total ;flow ;units: ;m 3 , L , G .

Communication

MODBUS ;protocol ( optional ) or ;HART ( optional )

Protection ;grade

IP65

Power ;supply

220 ;V ;AC ;+20/-60% ; , 50/60 ;Hz , 24 ;V ;DC ;+50/- 25% ; , max.10VA

EMC ;radiation ;standard

EN ;61326-1 : 2006 ; (BS ;EN50081-1)

EMC ;anti-jimming ;standard

EN ;61326-1: 2006 ;(BS ;EN50082-1)

CE ;security

EN ;61010-1 : 2001

Ambient ;temp.

5~55°C

Ambient ;humi d ity

<85 ;% ;r.h. ;(non  ; co n densation)

; ;
; ;